• Canada English (Canada)
  • Projects

Country and language

  • Germany

    Deutsch
  • France

    Français
  • Netherlands

    Nederlands
  • Switzerland

    DeutschFrançais
  • Austria

    Deutsch
  • Poland

    Polski
  • United Kingdom

    English (United Kingdom)
  • Canada

    English (Canada)Français (Canada)
  • Italy

    Italiano
  • USA

    English (United States)
  • Global

    EnglishРусский
  • Products
  • Tools
  • Service
  • Company
  • Magazine
  • Contact
      • ProductsArrow Right 1 Streamline Icon: https://streamlinehq.com
        • Trench TechnologyArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Katherm HK
          • Katherm QK
          • Katherm QK nano
          • Katherm NK
          • Katherm QE
        • Unit HeatersArrow Right 1 Streamline Icon: https://streamlinehq.com
          • TOP
        • Perimeter Heating
        • Fan Coils & Force FlowsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • KaDius
          • Venkon
          • KaDeck
          • PowerKon LT
          • Venkon XL
          • Baseboard HK
      • ToolsArrow Right 1 Streamline Icon: https://streamlinehq.com
        • Download Center
        • Calculation programs
      • ServiceArrow Right 1 Streamline Icon: https://streamlinehq.com
        • Customer Service
        • Project SupportArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Consulting
          • Design
          • Site measurement
          • Construction including Tailored Solutions
          • Delivery
      • CompanyArrow Right 1 Streamline Icon: https://streamlinehq.com
        • Kampmann Heating, Cooling, Ventilation Ltd.
        • Research and development
        • Sustainability
        • Compliance
      • MagazineArrow Right 1 Streamline Icon: https://streamlinehq.com
        • News
        • Technology and knowledge
      • ContactArrow Right 1 Streamline Icon: https://streamlinehq.com
        • Find Contact
        • Contact form
      • Home
      • Products
      • Trench Technology
      • Katherm Qk

      Products

      • Trench Technology
      • Unit Heaters
      • Fan Coils
      • Perimeter Heaters

      Company

      • Kampmann Heating, Cooling, Ventilation Ltd.
      • Research and Development
      • Sustainability
      • Magazine

      Service

      • Project Support
      • Customer Service
      • Contact

      Contact

      +1 250 826 0284info@kampmann.ca
      • Imprint
      • General Terms and Conditions
      • Central Data Protection Instructions
      • Cookies
      • Modern Slavery Statement
      • Reporting system
      • Compliance

      Our products are intended exclusively for B2B sales.

      Katherm QK

      Article no.: 14251113123324
      • Details
      • Description
      • Technical data
      • Acoustic data
      • EPD
      • Dimensions
      • Accessories
      • Downloads

      basic unit

      Kampmann Katherm QK trench heater, convector-based ready-to-install heating trenches for installation in the floor with tangential fan convection. Certified to UL 1995 and CSA C22.2#236.
      Trench chassis made of sendzimir galvanised sheet steel, coated in graphite gray. Height-adjustable mounting brackets on the sides with impact sound insulation; sturdy height adjustment mechanism with impact sound insulation. Includes cross braces to reinforce the trench chassis. With pre-punched connection openings for water supply and return as well as electrical connections, on the room side. With a frame edging profile color-matched to the grate. With standard protective cover and frame edge. With a cover plate over the connection area.
      Life Cycle Assessment (LCA) data is published in the form of an EPD according to EN 15804 and is available to download from the International EPD System. Registered in the building products platform DGNB Navigator. GWP (phase A1-A3), kg CO2 Äq.5,88E+01. Further calculations possible online.

      Heat exchanger

      High-performance heat exchanger made of circular copper pipes with aluminum fins and a Eurokonus valve connection, coated in graphite gray. With integral bleed option.
      System2-pipe
      Max. operating pressurebar10
      Max. entering water temperature°C95
      Min. entering water temperature°C15
      Max. air inlet temp.°C40

      Fan

      Tangential fan with safety guard and sound-decoupled mounting plates. Energy-saving EC fan with 0-10 V signal for continuously variable speed control. All rotating parts are silent and mounted on maintenance-free bearings. Factory-wired.

      Control

      24 V electromechanical control version
      Factory-fitted and wired in the unit. Connection options for on-site signals to control the fan (continuously variable) and actuators. Stepless speed control via an external 0-10VDC signal.
      Motor monitoring with integral shut-down in the event of faults.

      Grille

      With double T-profile grille. Connections made of corrosion-proof steel springs with matching spacers.

      Configuration

      Grille designLinear grille
      Grille finishAluminium, brass anodised
      Lengthmm1920
      Widthmm190
      Heightmm112
      Bar heightmm18
      Bar depthmm5
      Bar spacingmm12
      Free area, approx. %70
      Weightkg18.5

      Connection

      • left

      Simple coupling of trenches

      • Detachable headpiece
      • for easy coupling of the trench convectors
      • for attaching dummy sections, mitred corners etc.

      24V electromechanical control version

      • all factory-fitted components are wired to terminals
      • compact connecting terminal strip
      • convenient/space-saving connection area
      • power supply via on-site power supply components
      • control by Kampmann room thermostats or on-site controls

      Cover plate

      • serves as visual protection and to protect against dirt

      Control

      • power supply 24V
      • optional DIN rail Class 2 Transformers for 120V/60Hz supply
      • fan speed control 20 to 100 % via 0-10V BMS signal

      High-performance convector

      • for optimum heat dissipation
      • consists of a proven combination of copper and aluminium
      • optimised air flow and heat dissipation
      • painted graphite-grey

      Extra-long EC fan

      • with performance-increasing power stages for higher heat outputs
      • for even airflow through the coil
      • with sound-isolated mounting plates

      View

      • IFront view
      • IItop view (without cover panel)
      • IIICross-section, enlarged

      Further Information

      • 1window side
      • 2room side

      Specifications

      Article no.14251113123324
      Height112 mm
      Width190 mm
      Length (A)1,920 mm
      finned length (B)1,300 mm
      Water content1.1 l
      Weight18.5 kg

      We consider the environmental impact of our products throughout their entire life cycle! The result is Environmental Product Declarations (EPDs). The EPDs can be easily submitted to all common building sustainability certification systems, such as DGNB, BREEAM, or LEED, and are available in the download area or directly here via the download button. In addition, the product is registered on the DGNB Navigator building products platform.

      Basic data

      Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
      GWP - Total
      Climate change - total
      kg CO2 eq5.71E+011.58E+001.28E-015.88E+012.10E+004.49E-012.17E-015.82E-029.39E-014.81E+000.00E+007.18E-022.36E+003.58E-02-2.95E+01
      GWP - fossil
      Climate change - fossil
      kg CO2 eq5.63E+011.58E+002.15E+006.00E+012.10E+004.45E-012.04E-015.13E-029.34E-014.22E+000.00E+007.17E-022.36E+003.55E-02-2.92E+01
      GWP - Biogenic
      Climate change - biogenic
      kg CO2 eq3.34E-013.83E-03-2.02E+00-1.69E+002.72E-033.85E-038.79E-03-5.12E-03-2.20E-035.84E-010.00E+001.73E-044.53E-043.58E-04-2.23E-02
      GWP - Luluc
      Climate change - land use and land use change
      kg CO2 eq5.79E-015.95E-041.89E-035.82E-013.40E-044.45E-044.00E-031.19E-027.82E-035.78E-030.00E+002.69E-056.49E-053.60E-05-2.42E-01
      ODP
      Ozone Depletion
      kg CFC-11 eq4.03E-063.95E-074.03E-084.47E-064.90E-071.90E-081.73E-084.82E-097.25E-082.86E-070.00E+001.79E-082.21E-081.08E-08-2.05E-06
      AP
      Acidification
      mol H+ eq6.51E-015.09E-031.55E-026.72E-011.05E-021.85E-038.35E-043.88E-042.87E-021.33E-020.00E+002.28E-045.03E-042.99E-04-3.53E-01
      EP - Freshwater
      Eutrophication aquatic freshwater
      kg P eq5.21E-021.03E-042.59E-035.48E-026.34E-051.35E-044.18E-051.75E-052.27E-036.75E-040.00E+004.65E-061.83E-051.03E-05-2.99E-02
      EP - Marine
      Eutrophication aquatic marine
      kg P eq1.28E-011.14E-032.33E-031.31E-013.57E-035.02E-042.20E-048.58E-058.08E-033.12E-030.00E+005.11E-051.96E-041.03E-04-3.30E-02
      EP - Terrestrial
      Eutrophication terrestrial
      mol N eq7.23E-011.24E-022.06E-027.56E-013.91E-023.74E-032.00E-035.69E-042.37E-023.45E-020.00E+005.58E-042.00E-031.12E-03-3.77E-01
      POCP
      Photochemical ozone formation
      kg NMVOC2.14E-013.18E-035.51E-032.22E-019.50E-031.01E-034.36E-041.79E-046.04E-037.93E-030.00E+001.42E-044.64E-042.76E-04-1.12E-01
      ADPE
      Depletion of abiotic resources - minerals and metals
      kg Sb eq8.01E-033.79E-062.41E-068.02E-032.00E-062.74E-061.33E-068.50E-076.30E-041.19E-050.00E+001.72E-075.24E-071.16E-07-5.68E-03
      ADPF
      Abiotic resource depletion - fossil fuels
      MJ7.61E+022.58E+012.39E+018.10E+023.08E+019.57E+004.85E+006.69E-011.24E+011.12E+020.00E+001.17E+005.62E-018.33E-01-3.64E+02
      WDP
      Water use
      m³ depriv.2.80E+018.60E-022.98E-012.84E+015.06E-025.74E-016.39E-022.90E-026.64E-011.51E-010.00E+003.89E-033.74E-023.62E-02-5.14E+00
      GWP-GHG
      Global Warming Potential total excl. biogenic carbon following IPCC AR5 methodology
      kg CO2 eq5.54E+011.57E+002.12E+005.91E+012.09E+004.33E-012.02E-016.14E-029.20E-014.18E+000.00E+007.11E-023.55E-022.36E+00-2.83E+01
      PM
      Particulate Matter emissions
      disease inc.3.50E-061.39E-074.90E-083.69E-066.96E-083.01E-085.65E-093.63E-099.77E-085.96E-080.00E+006.27E-093.78E-095.80E-09-2.11E-06
      IR
      Ionizing radiation, human health
      kBq U-235 eq6.52E+001.30E-018.09E-026.73E+001.45E-013.12E-021.45E-012.48E-032.60E-013.95E+000.00E+005.89E-035.15E-033.93E-03-3.37E+00
      ETP - FW
      Ecotoxicity (fresh water)
      CTUe3.78E+032.01E+012.88E+013.83E+031.91E+011.04E+014.00E+001.73E+002.47E+025.24E+010.00E+009.09E-019.17E+005.93E-01-2.49E+03
      HTP - C
      Human toxicity, cancer effects
      CTUh2.56E-075.50E-107.85E-102.58E-073.60E-104.55E-098.90E-118.82E-118.23E-091.06E-090.00E+002.48E-113.42E-102.55E-11-1.53E-07
      HTP - NC
      Human toxicity, non-cancer effects
      CTUh5.36E-062.11E-083.29E-085.41E-062.69E-082.27E-082.50E-092.00E-093.68E-073.02E-080.00E+009.54E-104.26E-093.95E-10-3.84E-06
      SQP
      Land use related impacts/Soil quality
      -3.18E+023.06E+011.36E+024.85E+021.48E+011.22E+002.25E+001.02E+001.82E+014.23E+010.00E+001.39E+001.89E-012.06E+00-1.42E+02

      Resource use

      Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
      PERE
      Use of renewable primary energy excluding resources used as raw materials
      MJ1.72E+023.28E-012.61E+011.98E+022.07E-013.34E-011.03E+001.62E-013.24E+002.05E+010.00E+001.48E-025.79E-021.42E-02-7.36E+01
      PERM
      Use of renewable primary energy resources used as raw materials
      MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      PERT
      Total use of renewable primary energy
      MJ1.72E+023.28E-012.61E+011.98E+022.07E-013.34E-011.03E+001.62E-013.24E+002.05E+010.00E+001.48E-025.79E-021.42E-02-7.36E+01
      PENRE
      Use of non-renewable primary energy excluding resources used as raw materials
      MJ7.61E+022.58E+012.39E+018.10E+023.08E+019.57E+004.86E+006.84E-011.24E+011.12E+020.00E+001.17E+005.62E-018.33E-01-3.64E+02
      PENRM
      Use of non-renewable primary energy resources used as raw materials
      MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      PENRT
      Total use of non-renewable primary energy
      MJ7.61E+022.58E+012.39E+018.10E+023.08E+019.57E+004.86E+006.84E-011.24E+011.12E+020.00E+001.17E+005.62E-018.33E-01-3.64E+02
      SM
      Secondary material
      kg5.28E-020.00E+000.00E+005.28E-020.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      RSF
      Renewable secondary fuels
      MJ3.58E-040.00E+000.00E+003.58E-040.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      NRSF
      Non-renewable secondary fuels
      MJ2.30E-020.00E+000.00E+002.30E-020.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      FW
      Net use of fresh water
      m³6.20E-015.26E-038.46E-036.34E-013.78E-031.12E-023.50E-038.73E-042.63E-022.70E-020.00E+002.38E-041.30E-039.40E-04-1.82E-01

      Waste & Output Flows

      Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
      HWD
      Hazardous waste disposed
      kg2.79E+000.00E+000.00E+002.79E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      NHWD
      Non-hazardous waste disposed
      kg1.81E+000.00E+003.51E+005.32E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      RWD
      Radioactive waste disposed
      kg2.32E-030.00E+000.00E+002.32E-030.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      CRU
      Components for reuse
      kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      MFR
      Material for recycling
      kg9.02E-040.00E+000.00E+009.02E-040.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+001.07E+010.00E+000.00E+00
      MER
      Materials for energy recovery
      kg3.97E-060.00E+000.00E+003.97E-060.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+008.73E-010.00E+000.00E+00
      EE (Electrical)
      Exported energy electrical
      MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      EE (Thermal)
      Exported energy thermal
      MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00