• Canada English (Canada)
  • Projects

Country and language

  • Germany

    Deutsch
  • France

    Français
  • Netherlands

    Nederlands
  • Switzerland

    DeutschFrançais
  • Austria

    Deutsch
  • Poland

    Polski
  • United Kingdom

    English (United Kingdom)
  • Canada

    English (Canada)Français (Canada)
  • Italy

    Italiano
  • USA

    English (United States)
  • Global

    EnglishРусский
  • Products
  • Tools
  • Service
  • Company
  • Magazine
  • Contact
        • ProductsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Trench TechnologyArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Katherm HK
            • Katherm QK
            • Katherm QK nano
            • Katherm NK
            • Katherm QE
          • Unit HeatersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • TOP
          • Perimeter Heating
          • Fan Coils & Force FlowsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • KaDius
            • Venkon
            • KaDeck
            • PowerKon LT
            • Venkon XL
            • Baseboard HK
        • ToolsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Download Center
          • Calculation programs
        • ServiceArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Customer Service
          • Project SupportArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Consulting
            • Design
            • Site measurement
            • Construction including Tailored Solutions
            • Delivery
        • CompanyArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Kampmann Heating, Cooling, Ventilation Ltd.
          • Research and development
          • Sustainability
          • Compliance
        • MagazineArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Technology and knowledge
          • News
        • ContactArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Find Contact
          • Contact form
        • Home
        • Products
        • Trench Technology
        • Katherm Qk

        Products

        • Trench Technology
        • Unit Heaters
        • Fan Coils
        • Perimeter Heaters

        Company

        • Kampmann Heating, Cooling, Ventilation Ltd.
        • Research and Development
        • Sustainability
        • Magazine

        Service

        • Project Support
        • Customer Service
        • Contact

        Contact

        +1 250 826 0284info@kampmann.ca
        • Imprint
        • General Terms and Conditions
        • Central Data Protection Instructions
        • Cookies
        • Modern Slavery Statement
        • Reporting system
        • Compliance

        Our products are intended exclusively for B2B sales.

        Katherm QK

        Article no.: 14254101141024
        • Details
        • Description
        • Technical data
        • Acoustic data
        • EPD
        • Dimensions
        • Accessories
        • Downloads

        basic unit

        Kampmann Katherm QK trench heater, convector-based ready-to-install heating trenches for installation in the floor with tangential fan convection. Certified to UL 1995 and CSA C22.2#236.
        Trench chassis made of sendzimir galvanised sheet steel, coated in graphite gray. Height-adjustable mounting brackets on the sides with impact sound insulation; sturdy height adjustment mechanism with impact sound insulation. Includes cross braces to reinforce the trench chassis. With pre-punched connection openings for water supply and return as well as electrical connections, on the room side. With a frame edging profile color-matched to the grate. With standard protective cover and frame edge. With a cover plate over the connection area.
        Life Cycle Assessment (LCA) data is published in the form of an EPD according to EN 15804 and is available to download from the International EPD System. Registered in the building products platform DGNB Navigator. GWP (phase A1-A3), kg CO2 Äq.2,69E+01. Further calculations possible online.

        Heat exchanger

        High-performance heat exchanger made of circular copper pipes with aluminum fins and a Eurokonus valve connection, coated in graphite gray. With integral bleed option.
        System2-pipe
        Max. operating pressurebar10
        Max. entering water temperature°C95
        Min. entering water temperature°C15
        Max. air inlet temp.°C40

        Fan

        Tangential fan with safety guard and sound-decoupled mounting plates. Energy-saving EC fan with 0-10 V signal for continuously variable speed control. All rotating parts are silent and mounted on maintenance-free bearings. Factory-wired.

        Control

        24 V electromechanical control version
        Factory-fitted and wired in the unit. Connection options for on-site signals to control the fan (continuously variable) and actuators. Stepless speed control via an external 0-10VDC signal.
        Motor monitoring with integral shut-down in the event of faults.

        Grille

        With double T-profile grille. Connections made of corrosion-proof steel springs with matching spacers.

        Configuration

        Grille designRoll-up grille
        Grille finishAluminium, black anodised
        Lengthmm780
        Widthmm215
        Heightmm96
        Bar heightmm18
        Bar depthmm5
        Bar spacingmm9
        Free area, approx. %65
        Weightkg8.9

        Connection

        • left

        Simple coupling of trenches

        • Detachable headpiece
        • for easy coupling of the trench convectors
        • for attaching dummy sections, mitred corners etc.

        24V electromechanical control version

        • all factory-fitted components are wired to terminals
        • compact connecting terminal strip
        • convenient/space-saving connection area
        • power supply via on-site power supply components
        • control by Kampmann room thermostats or on-site controls

        Cover plate

        • serves as visual protection and to protect against dirt

        Control

        • power supply 24V
        • optional DIN rail Class 2 Transformers for 120V/60Hz supply
        • fan speed control 20 to 100 % via 0-10V BMS signal

        High-performance convector

        • for optimum heat dissipation
        • consists of a proven combination of copper and aluminium
        • optimised air flow and heat dissipation
        • painted graphite-grey

        Extra-long EC fan

        • with performance-increasing power stages for higher heat outputs
        • for even airflow through the coil
        • with sound-isolated mounting plates

        • IFront view
        • IItop view (without cover panel)
        • IIICross-section, enlarged

        • 1window side
        • 2room side

        Article no.14254101141024
        Height96 mm
        Width215 mm
        Length (A)780 mm
        Water content0.4 l
        Weight8.8 kg

        We consider the environmental impact of our products throughout their entire life cycle! The result is Environmental Product Declarations (EPDs). The EPDs can be easily submitted to all common building sustainability certification systems, such as DGNB, BREEAM, or LEED, and are available in the download area or directly here via the download button. In addition, the product is registered on the DGNB Navigator building products platform.

        Basic data

        Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
        GWP - Total
        Climate change - total
        kg CO2 eq2.61E+017.24E-015.83E-022.69E+019.59E-012.05E-019.93E-022.66E-024.29E-012.20E+000.00E+003.28E-021.08E+001.64E-02-1.35E+01
        GWP - fossil
        Climate change - fossil
        kg CO2 eq2.57E+017.24E-019.82E-012.74E+019.59E-012.04E-019.31E-022.34E-024.27E-011.93E+000.00E+003.28E-021.08E+001.62E-02-1.34E+01
        GWP - Biogenic
        Climate change - biogenic
        kg CO2 eq1.53E-011.75E-03-9.26E-01-7.71E-011.25E-031.76E-034.02E-03-2.34E-03-1.00E-032.67E-010.00E+007.91E-052.07E-041.64E-04-1.02E-02
        GWP - Luluc
        Climate change - land use and land use change
        kg CO2 eq2.65E-012.72E-048.64E-042.66E-011.55E-042.04E-041.83E-035.45E-033.57E-032.64E-030.00E+001.23E-052.97E-051.64E-05-1.11E-01
        ODP
        Ozone Depletion
        kg CFC-11 eq1.84E-061.81E-071.84E-082.04E-062.24E-078.70E-097.91E-092.20E-093.32E-081.31E-070.00E+008.19E-091.01E-084.93E-09-9.37E-07
        AP
        Acidification
        mol H+ eq2.98E-012.33E-037.07E-033.07E-014.78E-038.47E-043.81E-041.77E-041.31E-026.06E-030.00E+001.04E-042.30E-041.37E-04-1.62E-01
        EP - fresh water
        Eutrophication aquatic freshwater
        kg P eq2.38E-024.70E-051.18E-032.51E-022.90E-056.17E-051.91E-058.02E-061.04E-033.09E-040.00E+002.13E-068.36E-064.71E-06-1.37E-02
        EP - marine
        Eutrophication aquatic marine
        kg P eq5.83E-025.21E-041.07E-035.99E-021.63E-032.29E-041.00E-043.92E-053.69E-031.42E-030.00E+002.33E-058.98E-054.71E-05-1.51E-02
        EP - country
        Eutrophication terrestrial
        mol N eq3.30E-015.67E-039.42E-033.45E-011.79E-021.71E-039.14E-042.60E-041.08E-021.58E-020.00E+002.55E-049.14E-045.13E-04-1.72E-01
        POCP
        Photochemical ozone formation
        kg NMVOC9.77E-021.45E-032.52E-031.02E-014.34E-034.62E-041.99E-048.19E-052.76E-033.62E-030.00E+006.51E-052.12E-041.26E-04-5.10E-02
        ADPE
        Depletion of abiotic resources - minerals and metals
        kg Sb eq3.66E-031.73E-061.10E-063.66E-039.14E-071.25E-066.06E-073.89E-072.88E-045.45E-060.00E+007.85E-082.40E-075.30E-08-2.60E-03
        ADPF
        Abiotic resource depletion - fossil fuels
        MJ3.48E+021.18E+011.09E+013.70E+021.41E+014.38E+002.22E+003.06E-015.67E+005.14E+010.00E+005.33E-012.57E-013.81E-01-1.67E+02
        WDP
        Water use
        m³ depriv.1.28E+013.93E-021.36E-011.30E+012.31E-022.63E-012.92E-021.32E-023.03E-016.90E-020.00E+001.78E-031.71E-021.65E-02-2.35E+00
        GWP-GHG
        Global Warming Potential total excl. biogenic carbon following IPCC AR5 methodology
        kg CO2 eq2.53E+017.18E-019.71E-012.70E+019.54E-011.98E-019.26E-022.80E-024.21E-011.91E+000.00E+003.25E-021.62E-021.08E+00-1.30E+01
        PM
        Particulate Matter emissions
        disease inc.1.60E-066.34E-082.24E-081.69E-063.18E-081.37E-082.58E-091.66E-094.47E-082.73E-080.00E+002.87E-091.73E-092.65E-09-9.65E-07
        IR
        Ionizing radiation, human health
        kBq U-235 eq2.98E+005.95E-023.70E-023.08E+006.62E-021.42E-026.62E-021.13E-031.19E-011.81E+000.00E+002.69E-032.36E-031.80E-03-1.54E+00
        ETP - FW
        Ecotoxicity (fresh water)
        CTUe1.73E+039.20E+001.32E+011.75E+038.75E+004.75E+001.83E+007.91E-011.13E+022.40E+010.00E+004.16E-014.19E+002.71E-01-1.14E+03
        HTP - C
        Human toxicity, cancer effects
        CTUh1.17E-072.51E-103.59E-101.18E-071.64E-102.08E-094.07E-114.03E-113.76E-094.85E-100.00E+001.13E-111.57E-101.17E-11-7.01E-08
        HTP - NC
        Human toxicity, non-cancer effects
        CTUh2.45E-069.65E-091.50E-082.47E-061.23E-081.04E-081.14E-099.14E-101.68E-071.38E-080.00E+004.36E-101.95E-091.81E-10-1.76E-06
        SQP
        Land use related impacts/Soil quality
        -1.45E+021.40E+016.23E+012.22E+026.79E+005.56E-011.03E+004.68E-018.30E+001.94E+010.00E+006.34E-018.64E-029.42E-01-6.51E+01

        Resource use

        Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
        PERE
        Use of renewable primary energy excluding resources used as raw materials
        MJ7.86E+011.50E-011.19E+019.07E+019.48E-021.53E-014.71E-017.40E-021.48E+009.37E+000.00E+006.79E-032.65E-026.51E-03-3.37E+01
        PERM
        Use of renewable primary energy resources used as raw materials
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        PERT
        Total use of renewable primary energy
        MJ7.86E+011.50E-011.19E+019.07E+019.48E-021.53E-014.71E-017.40E-021.48E+009.37E+000.00E+006.79E-032.65E-026.51E-03-3.37E+01
        PENRE
        Use of non-renewable primary energy excluding resources used as raw materials
        MJ3.48E+021.18E+011.09E+013.70E+021.41E+014.38E+002.22E+003.12E-015.67E+005.14E+010.00E+005.33E-012.57E-013.81E-01-1.67E+02
        PENRM
        Use of non-renewable primary energy resources used as raw materials
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        PENRT
        Total use of non-renewable primary energy
        MJ3.48E+021.18E+011.09E+013.70E+021.41E+014.38E+002.22E+003.12E-015.67E+005.14E+010.00E+005.33E-012.57E-013.81E-01-1.67E+02
        SM
        Secondary material
        kg2.41E-020.00E+000.00E+002.41E-020.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        RSF
        Renewable secondary fuels
        MJ1.64E-040.00E+000.00E+001.64E-040.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        NRSF
        Non-renewable secondary fuels
        MJ1.05E-020.00E+000.00E+001.05E-020.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        FW
        Net use of fresh water
        m³2.83E-012.41E-033.87E-032.90E-011.73E-035.14E-031.60E-033.99E-041.20E-021.23E-020.00E+001.09E-045.95E-044.30E-04-8.30E-02

        Waste & Output Flows

        Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
        HWD
        Hazardous waste disposed
        kg1.28E+000.00E+000.00E+001.28E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        NHWD
        Non-hazardous waste disposed
        kg8.29E-010.00E+001.60E+002.43E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        RWD
        Radioactive waste disposed
        kg1.06E-030.00E+000.00E+001.06E-030.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        CRU
        Components for reuse
        kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        MFR
        Material for recycling
        kg4.12E-040.00E+000.00E+004.12E-040.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+004.87E+000.00E+000.00E+00
        MER
        Materials for energy recovery
        kg1.82E-060.00E+000.00E+001.82E-060.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+003.99E-010.00E+000.00E+00
        EE (Electrical)
        Exported energy electrical
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        EE (Thermal)
        Exported energy thermal
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00