Trench Technology
Katherm HK
Article no.:
14332431131924
List price
1,706.00 CAD
zzgl. 19% MwSt.
Overview
- Energy-saving, with flow-optimised impellers, cascaded arrangement as a continuous fan belt
- Easily removeable, plug & play fan
- Even air flow through convector
- Robust and whisper-quiet motor design
- Continuously variable control via external 0-10 V signal
- All factory-fitted components are wired to terminals
- Compact connecting terminal strip
- Convenient/space-saving connection area
- Power supply via on-site power supply components
- Control by Kampmann room thermostats or on-site controls
Easy removal of tangential fan without tool
Novl coupling/cone pin system
Simultaneous sound decoupling
Act as a finger guard for the tangential fan, filter frame, airflow baffle, grille seat and reinforcing stay to strengthen the trenchAct as a finger guard for the tangential fan, filter frame, airflow baffle, grille seat and reinforcing stay to strengthen the trench
With anti-torsion device
Made of the proven copper/aluminium combination, optimised for air flow and output
Optionally available with projecting connections
Painted graphite-grey
- For inducing preconditioned supply air
- Primary air volume can be adjusted
- Max. air volume per module = 35 cfm (60 m³/h)
- Amount of modules selectable depending on trench length
- Change in trench dimensions: trench width + 0.79“ (20 mm); trench height + 1.38“ (35 mm)
Calculate performance data
Sound power octave spectrum
The sound power is determined depending on the use according to DIN EN ISO 3741 (in the echo chamber), according to DIN EN ISO 3744 (in the low-reflective half-space) or according to DIN EN ISO 9614 (intensity method).
Oktave Spektrum
EPD data
Item number-specific LCA data based on verified EPD according to EN 15804, which is available for download at The International EPD System. Separate subdivision of life cycle modules available online via button "EPD data sheet". The environmental impacts of module B refer to 1 year of operation. A: Product and construction process stage - B: Use stage - C: End of life stage - D: Benefits and loads beyond the system boundary
A | B | C | D | |
---|---|---|---|---|
GWP - Total kg CO2 eq | 8.35E+01 | 6.38E+00 | 3.27E+00 | -3.76E+01 |
GWP - fossil kg CO2 eq | 8.52E+01 | 5.69E+00 | 3.27E+00 | -3.72E+01 |
GWP - Biogenic kg CO2 eq | -2.48E+00 | 6.65E-01 | 1.29E-03 | -1.81E-02 |
GWP - Luluc kg CO2 eq | 8.51E-01 | 2.20E-02 | 1.60E-04 | -2.70E-01 |
ODP kg CFC-11 eq | 6.94E-06 | 3.84E-07 | 6.42E-08 | -2.51E-06 |
AP mol H+ eq | 9.35E-01 | 4.61E-02 | 1.33E-03 | -5.45E-01 |
EP - fresh water kg P eq | 8.17E-02 | 3.92E-03 | 4.21E-05 | -4.52E-02 |
EP - marine kg P eq | 9.79E-02 | 5.39E-03 | 4.50E-04 | -4.65E-02 |
EP - country mol N eq | 1.06E+00 | 6.37E-02 | 5.17E-03 | -5.40E-01 |
POCP kg NMVOC | 3.10E-01 | 1.60E-02 | 1.13E-03 | -1.56E-01 |
ADPE kg Sb eq | 1.30E-02 | 1.31E-03 | 1.01E-06 | -1.03E-02 |
ADPF MJ | 1.15E+03 | 1.41E+02 | 3.33E+00 | -4.59E+02 |
WDP m³ depriv. | 2.22E+01 | 9.08E-01 | 1.02E-01 | -8.06E+00 |
GWP-GHG kg CO2 eq | 8.35E+01 | 5.65E+00 | 3.27E+00 | -3.62E+01 |
PM disease inc. | 6.24E-06 | 1.66E-07 | 2.02E-08 | -2.83E-06 |
IR kBq U-235 eq | 1.29E+01 | 4.65E+00 | 1.94E-02 | -3.97E+00 |
ETP - FW CTUe | 5.96E+03 | 3.10E+02 | 1.36E+01 | -3.99E+03 |
HTP - C CTUh | 4.17E-07 | 1.08E-08 | 4.31E-10 | -2.12E-07 |
HTP - NC CTUh | 9.45E-06 | 4.49E-07 | 6.92E-09 | -6.23E-06 |
SQP - | 6.62E+02 | 6.23E+01 | 4.73E+00 | -2.18E+02 |
PERE MJ | 3.16E+02 | 2.61E+01 | 1.09E-01 | -8.79E+01 |
PERM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PERT MJ | 3.16E+02 | 2.61E+01 | 1.09E-01 | -8.79E+01 |
PENRE MJ | 1.15E+03 | 1.41E+02 | 3.33E+00 | -4.59E+02 |
PENRM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PENRT MJ | 1.15E+03 | 1.41E+02 | 3.33E+00 | -4.59E+02 |
SM kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NRSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
FW m³ | 5.44E-01 | 5.69E-02 | 4.19E-03 | -2.55E-01 |
HWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NHWD kg | 4.56E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
CRU kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
MFR kg | 0.00E+00 | 0.00E+00 | 1.38E+01 | 0.00E+00 |
MER kg | 0.00E+00 | 0.00E+00 | 1.09E+00 | 0.00E+00 |
EE (Electrical) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
EE (Thermal) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
Accessories
Control accessories electromechanical 24 V
power supply unit
for external installation outside the trench heater, 86 - 264 V AC, 24 V DC, 47 Hz, 60 W, on DIN rail, Protection class II
Suitable for: EC units, electromechanical 24 V, 2, 5, 6, Katherm QK, Katherm QK nano, PowerKon nano and Trench Technology, Trench Technology, Perimeter Heating
Suitable for: EC units, electromechanical 24 V, 2, 5, 6, Katherm QK, Katherm QK nano, PowerKon nano and Trench Technology, Trench Technology, Perimeter Heating
Article no.:
196901338401
List price
74.00 CAD
zzgl. 19% MwSt.
power supply unit
for external installation outside the trench heater, 86 - 264 V AC, 24 V DC, 47 Hz, 92 W, on DIN rail, Protection class II
Suitable for: EC units, electromechanical 24 V, 4, 7, 10, Katherm QK, Katherm QK nano, PowerKon nano and Trench Technology, Trench Technology, Perimeter Heating
Suitable for: EC units, electromechanical 24 V, 4, 7, 10, Katherm QK, Katherm QK nano, PowerKon nano and Trench Technology, Trench Technology, Perimeter Heating
Article no.:
196901338402
List price
106.00 CAD
zzgl. 19% MwSt.
Filter
Filter for air inlet
2- and 4-pipe, Replacement filter without frame, ISO Coarse 30% filter (G2)
Suitable for: Length 1200 mm
Suitable for: Length 1200 mm
Article no.:
143014313019
List price
23.00 CAD
zzgl. 19% MwSt.
Installation covers
Installation cover
to protect trench during installation, factory-fitted, grilles are packed separately
price per m
price per m
Article no.:
194000100320
List price
22.00 CAD
zzgl. 19% MwSt.
Downloads
Declarations/Certificates
Certificate ISO 50001:2018
PDF
(116 kB)
Digital EPD database Katherm HK E
Digital EPD database Katherm HK
EPD Katherm HK E
PDF
(1.6 MB)
ETL Authorisation to mark Katherm and Baseboard HK and QK
PDF
(100 kB)
EPD Katherm HK
PDF
(2.5 MB)
Cross-product information
Products
PDF
(7.5 MB)
Overview Katherm supply air versions
PDF
(4.1 MB)
Overview Trench Systems
PDF
(3.3 MB)
BIM data (Building Information Modeling)
Kampmann Group BIM data
Technical catalogues
Katherm HK trench heating
PDF
(17.3 MB)
Manuals
Katherm HK trench heating
PDF
(5.5 MB)
Katherm HK, brief instructions
PDF
(3.8 MB)
CAD-Drawings
Katherm HK 320, 4-pipe, top view
PDF
(108 kB)
Katherm HK 320, 4-pipe, cross sections
PDF
(102 kB)
Katherm HK, trench width 320 mm, 4-pipe system
PDF
(145 kB)
Katherm HK, trench width 320 mm, 4-pipe system
PDF
(100 kB)
Katherm HK 320, 4-pipe, top view
DWG
(380 kB)
Katherm HK 320, 4-pipe, cross sections
DWG
(263 kB)
Katherm HK, trench width 320 mm, 4-pipe system
DXF
(2.7 MB)
Katherm HK, trench width 320 mm, 4-pipe system
DWG
(731 kB)
Katherm HK, trench width 320 mm, 4-pipe system
DXF
(4.5 MB)
Katherm HK, trench width 320 mm, 4-pipe system
DWG
(1.1 MB)