Trench Technology
Katherm QK nano
Article no.:
44217074234724
List price
2,449.00 CAD
zzgl. 19% MwSt.
Overview
- All factory-fitted components are wired to terminals
- Compact connecting terminal strip
- Convenient/space-saving connection area
- Power supply via on-site power supply components
- Control by Kampmann room thermostats or on-site controls
The Eurokonus valve connection enables the Katherm QK nano to be quickly and easily installed on site. In addition, height adjustment feet and raised floor height adjustment feet are supplied as standard to further reduce the installation time and thus the cost.
- For valves and electrical components
- With cover for visual protection and to protect against dirt
- Prevents damage to the convector when installing the valves or threaded connectors
- For the simple fixing of the floor trench
- With rubber underlay for acoustic decoupling
- Power supply 24V
- Available in 30, 60 and 100 W versions
- Optional DIN rail Class 2 Transformers for 120V/60Hz supply
- Fan speed control 20 to 100 % via 0-10V BMS signal
24 V electromechanical
Calculate performance data
Sound power octave spectrum
The sound power is determined depending on the use according to DIN EN ISO 3741 (in the echo chamber), according to DIN EN ISO 3744 (in the low-reflective half-space) or according to DIN EN ISO 9614 (intensity method).
Oktave Spektrum
EPD data
Item number-specific LCA data based on verified EPD according to EN 15804, which is available for download at The International EPD System. Separate subdivision of life cycle modules available online via button "EPD data sheet". The environmental impacts of module B refer to 1 year of operation. A: Product and construction process stage - B: Use stage - C: End of life stage - D: Benefits and loads beyond the system boundary
A | B | C | D | |
---|---|---|---|---|
GWP - Total kg CO2 eq | 6.75E+01 | 6.20E+00 | 4.12E+00 | -3.49E+01 |
GWP - fossil kg CO2 eq | 6.71E+01 | 6.16E+00 | 4.12E+00 | -3.45E+01 |
GWP - Biogenic kg CO2 eq | 1.16E-01 | 8.81E-03 | 5.19E-04 | -5.72E-02 |
GWP - Luluc kg CO2 eq | 2.70E-01 | 3.59E-02 | 3.25E-04 | -1.90E-01 |
ODP kg CFC-11 eq | 2.26E-06 | 2.71E-07 | 7.47E-08 | -8.82E-07 |
AP mol H+ eq | 8.43E-01 | 6.55E-02 | 1.85E-03 | -5.40E-01 |
EP - fresh water kg P eq | 7.16E-02 | 4.80E-03 | 8.42E-05 | -4.51E-02 |
EP - marine kg P eq | 1.63E-01 | 1.47E-02 | 6.31E-04 | -4.52E-02 |
EP - country mol N eq | 9.79E-01 | 8.12E-02 | 6.45E-03 | -5.38E-01 |
POCP kg NMVOC | 3.67E-01 | 2.38E-02 | 2.08E-03 | -2.14E-01 |
ADPE kg Sb eq | 7.69E-03 | 6.79E-04 | 1.54E-06 | -5.55E-03 |
ADPF MJ | 8.78E+02 | 1.41E+02 | 4.37E+00 | -4.23E+02 |
WDP m³ depriv. | 1.84E+01 | 1.04E+00 | 1.77E-01 | -7.82E+00 |
GWP-GHG kg CO2 eq | 6.76E+01 | 6.21E+00 | 4.12E+00 | -3.49E+01 |
PM disease inc. | 5.48E-06 | 2.48E-07 | 2.75E-08 | -2.82E-06 |
IR kBq U-235 eq | 6.86E+00 | 4.50E+00 | 2.02E-02 | -2.84E+00 |
ETP - FW CTUe | 1.30E+03 | 1.14E+02 | 3.16E+01 | -6.02E+02 |
HTP - C CTUh | 3.41E-07 | 1.26E-08 | 6.76E-10 | -1.91E-07 |
HTP - NC CTUh | 8.40E-06 | 6.96E-07 | 7.61E-09 | -5.87E-06 |
SQP - | 5.88E+02 | 7.78E+01 | 4.42E+00 | -1.80E+02 |
PERE MJ | 1.54E+02 | 3.20E+01 | 2.52E-01 | -6.81E+01 |
PERM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PERT MJ | 1.54E+02 | 3.20E+01 | 2.52E-01 | -6.81E+01 |
PENRE MJ | 8.78E+02 | 1.41E+02 | 4.37E+00 | -4.23E+02 |
PENRM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PENRT MJ | 8.78E+02 | 1.41E+02 | 4.37E+00 | -4.23E+02 |
SM kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NRSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
FW m³ | 6.76E-01 | 7.60E-02 | 4.54E-03 | -2.69E-01 |
HWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NHWD kg | 4.30E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
CRU kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
MFR kg | 0.00E+00 | 0.00E+00 | 1.32E+01 | 0.00E+00 |
MER kg | 0.00E+00 | 0.00E+00 | 1.57E+00 | 0.00E+00 |
EE (Electrical) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
EE (Thermal) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
Accessories
Control accessories electromechanical 24 V
power supply unit
for external installation outside the trench heater, 85 - 264 V AC, 24 V DC, 36 W, on DIN rail, Protection class II
Suitable for: EC units, electromechanical 24 V, 1, 3, 3, Katherm QK, Katherm QK nano, PowerKon nano and Trench Technology, Trench Technology, Perimeter Heating
Suitable for: EC units, electromechanical 24 V, 1, 3, 3, Katherm QK, Katherm QK nano, PowerKon nano and Trench Technology, Trench Technology, Perimeter Heating
Article no.:
196901335152
List price
56.00 CAD
zzgl. 19% MwSt.
power supply unit
for external installation outside the trench heater, 86 - 264 V AC, 24 V DC, 47 Hz, 60 W, on DIN rail, Protection class II
Suitable for: EC units, electromechanical 24 V, 2, 5, 6, Katherm QK, Katherm QK nano, PowerKon nano and Trench Technology, Trench Technology, Perimeter Heating
Suitable for: EC units, electromechanical 24 V, 2, 5, 6, Katherm QK, Katherm QK nano, PowerKon nano and Trench Technology, Trench Technology, Perimeter Heating
Article no.:
196901338401
List price
74.00 CAD
zzgl. 19% MwSt.
power supply unit
for external installation outside the trench heater, 86 - 264 V AC, 24 V DC, 47 Hz, 92 W, on DIN rail, Protection class II
Suitable for: EC units, electromechanical 24 V, 4, 7, 10, Katherm QK, Katherm QK nano, PowerKon nano and Trench Technology, Trench Technology, Perimeter Heating
Suitable for: EC units, electromechanical 24 V, 4, 7, 10, Katherm QK, Katherm QK nano, PowerKon nano and Trench Technology, Trench Technology, Perimeter Heating
Article no.:
196901338402
List price
106.00 CAD
zzgl. 19% MwSt.
Valve kits
Valve kit
Includes 1x pre-settable axial valve, 1x return shut-off valve, straight, matching spacer, Max. operating pressure 10 bar
Suitable for: Katherm QK nano and Trench Technology, DN 15
Suitable for: Katherm QK nano and Trench Technology, DN 15
Article no.:
194000442110
List price
87.00 CAD
zzgl. 19% MwSt.
Connection accessories
Connection set
with two return shut-off valves and matching adapter; when using the Katherm QK nano with a central manifold
Suitable for: Katherm QK nano
Suitable for: Katherm QK nano
Article no.:
194000442101
List price
75.00 CAD
zzgl. 19% MwSt.
Installation covers
Installation cover
to protect trench during installation, factory-fitted, grilles are packed separately
price per m
Suitable for: Katherm QK nano
price per m
Suitable for: Katherm QK nano
Article no.:
194000101916
List price
15.00 CAD
zzgl. 19% MwSt.
Downloads
Declarations/Certificates
Certificate ISO 50001:2018
PDF
(116 kB)
Digital EPD database Katherm QK nano
EPD Katherm QK nano
PDF
(9.3 MB)
ETL Authorisation to mark Katherm and Baseboard HK and QK
PDF
(100 kB)
Cross-product information
Products
PDF
(7.5 MB)
Overview Katherm supply air versions
PDF
(4.1 MB)
Overview Trench Systems
PDF
(3.3 MB)
BIM data (Building Information Modeling)
Kampmann Group BIM data
Manuals
Katherm QK nano trench heating
PDF
(1.6 MB)
Installation plans
Katherm QK nano, 24 V electromechanical model
PDF
(685 kB)
CAD-Drawings
Katherm QK nano, trench length 2600 mm, 24 V control, cross-sections, views
PDF
(129 kB)
Katherm QK nano, trench length 2600 mm, 24 V control, cross-sections, views
DWG
(440 kB)
Katherm QK nano, trench length 2600 mm, 24 V control, cross-sections, views
DXF
(1.7 MB)