Trench Technology
                                                                    
                                                                                                            Katherm QK
                                    Article no.: 
                                    14254113142724
                                
                                                            List price
                                                                    2,205.00 CAD
                                                                zzgl. 19% MwSt.
                            Overview
- All factory-fitted components are wired to terminals
- Compact connecting terminal strip
- Convenient/space-saving connection area
- Power supply via on-site power supply components
- Control by Kampmann room thermostats or on-site controls
- Removable end piece to simplify the coupling of trenches
- Serves as visual protection and to protect against dirt
- For optimum heat dissipation
- Consists of a proven combination of copper and aluminium
- Optimised air flow and heat dissipation
- Painted graphite-grey
- Power supply 24V
- Optional DIN rail Class 2 Transformers for 120V/60Hz supply
- Fan speed control 20 to 100 % via 0-10V BMS signal
- With performance-increasing power stages for higher heat outputs
- For even airflow through the coil
- With sound-isolated mounting plates
Calculate performance data
Sound power octave spectrum
                    The sound power is determined depending on the use according to DIN EN ISO 3741 (in the echo chamber), according to DIN EN ISO 3744 (in the low-reflective half-space) or according to DIN EN ISO 9614 (intensity method).
                        Oktave Spektrum
                    EPD data
                    Item number-specific LCA data based on verified EPD according to EN 15804, which is available for download at The International EPD System. Separate subdivision of life cycle modules available online via button "EPD data sheet". The environmental impacts of module B refer to 1 year of operation. A: Product and construction process stage - B: Use stage - C: End of life stage - D: Benefits and loads beyond the system boundary
                        | A | B | C | D | |
|---|---|---|---|---|
| GWP - Total kg CO2 eq | 6.24E+01 | 5.08E+00 | 2.08E+00 | -2.48E+01 | 
| GWP - fossil kg CO2 eq | 6.30E+01 | 4.56E+00 | 2.08E+00 | -2.46E+01 | 
| GWP - Biogenic kg CO2 eq | -1.36E+00 | 4.94E-01 | 8.30E-04 | -1.88E-02 | 
| GWP - Luluc kg CO2 eq | 8.06E-01 | 2.49E-02 | 1.08E-04 | -2.04E-01 | 
| ODP kg CFC-11 eq | 5.37E-06 | 3.21E-07 | 4.28E-08 | -1.73E-06 | 
| AP mol H+ eq | 5.92E-01 | 3.64E-02 | 8.69E-04 | -2.98E-01 | 
| EP - fresh water kg P eq | 5.11E-02 | 2.53E-03 | 2.80E-05 | -2.53E-02 | 
| EP - marine kg P eq | 1.20E-01 | 9.70E-03 | 2.96E-04 | -2.78E-02 | 
| EP - country mol N eq | 7.22E-01 | 5.12E-02 | 3.10E-03 | -3.18E-01 | 
| POCP kg NMVOC | 2.14E-01 | 1.23E-02 | 7.44E-04 | -9.41E-02 | 
| ADPE kg Sb eq | 6.74E-03 | 5.43E-04 | 6.85E-07 | -4.79E-03 | 
| ADPF MJ | 8.65E+02 | 1.10E+02 | 2.16E+00 | -3.07E+02 | 
| WDP m³ depriv. | 1.49E+01 | 7.66E-01 | 6.54E-02 | -4.34E+00 | 
| GWP-GHG kg CO2 eq | 6.19E+01 | 4.53E+00 | 2.08E+00 | -2.39E+01 | 
| PM disease inc. | 4.50E-06 | 1.41E-07 | 1.34E-08 | -1.78E-06 | 
| IR kBq U-235 eq | 1.13E+01 | 3.68E+00 | 1.26E-02 | -2.85E+00 | 
| ETP - FW CTUe | 3.60E+03 | 2.57E+02 | 9.00E+00 | -2.10E+03 | 
| HTP - C CTUh | 2.83E-07 | 7.99E-09 | 3.31E-10 | -1.29E-07 | 
| HTP - NC CTUh | 5.44E-06 | 3.40E-07 | 4.73E-09 | -3.24E-06 | 
| SQP - | 4.60E+02 | 5.38E+01 | 3.07E+00 | -1.20E+02 | 
| PERE MJ | 2.46E+02 | 2.10E+01 | 7.34E-02 | -6.21E+01 | 
| PERM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 
| PERT MJ | 2.46E+02 | 2.10E+01 | 7.34E-02 | -6.21E+01 | 
| PENRE MJ | 8.65E+02 | 1.10E+02 | 2.16E+00 | -3.07E+02 | 
| PENRM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 
| PENRT MJ | 8.65E+02 | 1.10E+02 | 2.16E+00 | -3.07E+02 | 
| SM kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 
| RSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 
| NRSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 
| FW m³ | 4.27E-01 | 4.86E-02 | 2.09E-03 | -1.53E-01 | 
| HWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 
| NHWD kg | 2.96E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 
| RWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 
| CRU kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 
| MFR kg | 0.00E+00 | 0.00E+00 | 9.00E+00 | 0.00E+00 | 
| MER kg | 0.00E+00 | 0.00E+00 | 7.36E-01 | 0.00E+00 | 
| EE (Electrical) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 
| EE (Thermal) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 
Accessories
Control accessories electromechanical 24 V
                            
            power supply unit
                        for external installation outside the trench heater, 85 - 264 V AC, 24 V DC, 36 W, on DIN rail, Protection class II
                        
                        
Suitable for: EC units, electromechanical 24 V, 1 Katherm QK Trench Technology, 3 Katherm QK nano Trench Technology, 3 PowerKon nano Perimeter Heating
            Suitable for: EC units, electromechanical 24 V, 1 Katherm QK Trench Technology, 3 Katherm QK nano Trench Technology, 3 PowerKon nano Perimeter Heating
                        Article no.: 
                        196901335152
                    
                    List price
                        56.00 CAD
                        zzgl. 19% MwSt.
                    power supply unit
                        for external installation outside the trench heater, 86 - 264 V AC, 24 V DC, 47 Hz, 60 W, on DIN rail, Protection class II
                        
                        
Suitable for: EC units, electromechanical 24 V, 2 Katherm QK Trench Technology, 5 Katherm QK nano Trench Technology, 6 PowerKon nano Perimeter Heating
            Suitable for: EC units, electromechanical 24 V, 2 Katherm QK Trench Technology, 5 Katherm QK nano Trench Technology, 6 PowerKon nano Perimeter Heating
                        Article no.: 
                        196901338401
                    
                    List price
                        74.00 CAD
                        zzgl. 19% MwSt.
                    power supply unit
                        for external installation outside the trench heater, 86 - 264 V AC, 24 V DC, 47 Hz, 92 W, on DIN rail, Protection class II
                        
                        
Suitable for: EC units, electromechanical 24 V, 4 Katherm QK Trench Technology, 7 Katherm QK nano Trench Technology, 10 PowerKon nano Perimeter Heating
            Suitable for: EC units, electromechanical 24 V, 4 Katherm QK Trench Technology, 7 Katherm QK nano Trench Technology, 10 PowerKon nano Perimeter Heating
                        Article no.: 
                        196901338402
                    
                    List price
                        106.00 CAD
                        zzgl. 19% MwSt.
                    Installation covers
                            
            Installation cover
                        to protect trench during installation, factory-fitted, grilles are packed separately
price per m
                        
Suitable for: Katherm QK
            price per m
Suitable for: Katherm QK
                        Article no.: 
                        194000100922
                    
                    List price
                        18.00 CAD
                        zzgl. 19% MwSt.
                    Downloads
further product information
                Products
                                
                                    PDF
                                                                            (7.3 MB)
                                                                    
                                
                            Declarations/Certificates
                Certificate ISO 9001, 14001, 50001
                                
                                    PDF
                                                                            (116 kB)
                                                                    
                                
                            Digital EPD database Katherm QK
                                EPD for Katherm QK
                                
                                    PDF
                                                                            (2.7 MB)
                                                                    
                                
                            Manuals
                Katherm QK trench heating
                                
                                    PDF
                                                                            (2.8 MB)
                                                                    
                                
                            Installation plans
                Katherm QK, electromechanical control 24V
                                
                                    PDF
                                                                            (685 kB)
                                                                    
                                
                            CAD-Drawings
                Katherm QK, Kanalbreite 215 mm, Kanalhöhe 112 mm, 2-Leiter, Rostart Linearrost, Regelung 24V,  Abmessungen [Inch], PDF
                                
                                    PDF
                                                                            (682 kB)
                                                                    
                                
                            Katherm QK, Kanalbreite 215 mm, Kanalhöhe 112 mm, 2-Leiter, Rostart Linearrost, Regelung 24V,  Abmessungen [mm], PDF
                                
                                    PDF
                                                                            (683 kB)
                                                                    
                                
                            Katherm QK, Kanalbreite 215 mm, Kanalhöhe 112 mm, 2-Leiter, Rostart Linearrost, Regelung 24V, Abmessungen [mm], DWG
                                
                                    DWG
                                                                            (2.3 MB)
                                                                    
                                
                            Katherm QK, Kanalbreite 215 mm, Kanalhöhe 112 mm, 2-Leiter, Rostart Linearrost, Regelung 24V, Abmessungen [Inch], DWG
                                
                                    DWG
                                                                            (2.3 MB)
                                                                    
                                
                            